VIGANTICE, CZECH REPUBLIC
The lighting design of the workshop in a family house was created to determine the light intensity, its uniformity, and the position of the lights. The design required to get as much light as possible into the space at a low price, regardless of the quality and spectral composition of the light. So we used luminaires with cool white light, low CRI and high efficiency (164 lm/W). After the installation, we verified the results of the design with a spectrometer: vertical illumination on a motorcycle 1000 lux, horizontal illumination on a work table 1900 lux.